RF401 Series OS Revisions
Revision: 04
- Changed defaults so they are compatible w/CR1000: -Protocol: PB Aware, -RS232 baud rate: 38.4k,-CSI/O Mode: SDC7
- Added SDC addresses 10, 11
- Added ME baud rates. Rates are 9600, 19.2k, 38.4k, 57.6k, 115.2k
- Added SDC info bits; this will show up in datalogger settings as SDCx Info RF401 Vxx; where x is 7,8,10, or 11 (the SDC address that the device is on), and xx is the firmware version.
- Added PB Aware with ME Master configuration.
- Removed references to "CSDC"; now just SDC
- Changed the wording for COM2xx to RF400 CSI/O mode; it is now called ME Master.
- Changed the ME Master mode function so that no data received over RF initiates the CS I/O becoming active. CS I/O will only become active if the attached device (eg, COM220) raises its RING line. This prevents any "callbacks" for the modem to RF configuration. A datalogger must be present at the modem to RF base for callbacks to function.
- Removed RF signal strength based hop metric adjustment.
- Added retries in Transparent protocol.
- Added check to see if the entire PakBus packet coming in over RF was received before sending a beacon out in the PB Node configuration. This had caused RF interference in some instances
- Changed GetVariable so that it will return signal strength.