RETIRED ›
This product is no longer available and has been replaced by: COM220.
COM210E Phone Modem for Europe
Services Available
Repair No
Calibration No
Free Support No

Overview

To get the same functionality as the COM210E, choose the -UK option for the COM220.

The COM210E enabled communications between a computer and a Campbell data logger via a European public switched telephone network. A Hayes-compatible modem was required at the base-station computer while a COM210E was connected to the data logger at the field site. The COM210E's wide operating temperature range and minimal power requirements made it ideal for use at remote sites.

Read More

Images

Detailed Description

To get the same functionality as the COM210E, choose the -UK option for the COM220.

Note

Historically, the 10704 Power Adapter was available for connecting the COM210E to the CR500 with s/n 1764 or lower, and the CR10 with the silver or 8032 black wiring panel. The adapter applied a constant 12 V to the COM210E's serial I/O. This power adapter is no longer available.

Specifications

Operating Voltage 12 V
Active Current Drain 160 mA
Quiescent Current Drain 120 μA
Baud Rate 1200, 4800, 9600 bps
Operation Full-duplex over standard analog phone lines
Standard Operating Temperature Range -25° to +50°C
Extended Operating Temperature Range -55° to +85°C
Dimensions 16.0 x 4.3 x 9.1 cm (6.3 x 1.7 x 3.6 in.) with mounts
Weight 272 g (10 oz)

Compatibility

Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.

Data Loggers

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000 (retired)
CR10X (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR295X (retired)
CR3000 (retired)
CR500 (retired) Not compatible with CR500s with s/n 1764 or lower. Originally the 10704 Power Adapter was used to connect the COM210E to these data loggers. The 10704 adapter is no longer available.
CR5000 (retired)
CR510 (retired) Not compatible with the CR510's silver or 8032 black wiring panel. Originally the 10704 Power Adapter was used to connect the COM210E to these wiring panels. The 10704 adapter is no longer available.
CR800 (retired)
CR850 (retired)
CR9000 (retired) Although the CR9000 is compatible, the COM210E does not support its fastest communication rates, and is therefore not practical for most of its applications.
CR9000X (retired) Although the CR9000X is compatible, the COM210E does not support its fastest communication rates, and is therefore not practical for most of its applications.

Additional Compatibility Information

Power Considerations

The COM210E consumed 120 microAmps quiescent, 160 mA active (max). The data logger's power supply was sufficient for most applications.

Cabling

Data-logger-to-COM210E

An SC12 cable was provided for this purpose.

Phone Line-to-COM210E

Typically, a length of phone line was run from the telephone company's junction box to the COM210E's surge protector, and then to the Ground, Tip, and Ring terminals on the COM210E. Alternately, if adequate surge protection was provided by the telephone company and the junction box supports it, a length of telephone wire with RJ11C connectors (#2365) could be run directly from the junction box to the socket on the COM210E.

Surge Protection

If the local telephone company did not provide surge protection, either the 6362 or 4330 surge protector needed to be used. See "Ordering Info" tab for more information.

Enclosures

The COM210E required a desiccated, non-condensing environment; a Campbell Scientific enclosure was recommended. Grommets and screws were provided to attach the COM210E to the backplate of our enclosures.

Software

LoggerNet and PC400 software are compatible with the COM210E. Both of these software packages provide automated error-checking or user-initiated contacts. LoggerNet also supports scheduled contact times. Our software can run unattended allowing the user to take advantage of lower off-hour telephone rates.

Documents

Privacy Policy Update

We've updated our privacy policy.  Learn More

Cookie Consent

Update your cookie preferences.  Update Cookie Preferences