The 4731 is a power adapter manufactured by Mean Well that takes universal inputs (90 to 264 Vac, 47 to 63 Hz) and outputs 24 Vdc at 1.5 A. It float charges the sealed rechargeable batteries of the ET107 weather station via ac power. It can also be used with some retired weather stations such as the ET106, W2000, NW8000 series, and 010 series. The 4731 is included in the 10522 ac-power kit for ET stations.
-NOTE- | Additional specifications are listed in the 4731 Specifications Sheet. This information is provided by Mean Well. |
Dimensions | 14.8 x 4.0 x 3.0 cm (5.8 x 1.6 x 1.2 in.) |
Output |
|
DC Voltage | 24 V |
Rated Current | 1.5 A |
Current Range | 0 to 1.5 A |
Rated Power | 36 W |
Ripple & Noise | 150 mVp-p (measured at 20 MHz of bandwidth by using a 12-in. twisted pair-wire terminated with a 0.1uf and 47uf parallel capacitor) |
Voltage Tolerance | ±5.0% (includes setup tolerance, line regulation, and load regulation) |
Line Regulation | ±1.0% |
Load Regulation | ±2.0% |
Input |
|
Voltage Range | 90 to 264 Vac, 127 to 370 Vdc |
Frequency Range | 47 to 63 Hz |
Efficiency | 85% (typical) |
AC Current |
|
Protection |
|
Overload | 110 to 150% rated output power |
Overload Protection Type | Hiccup mode (Recovers automatically after fault condition is removed.) |
Overvoltage | 27.6 to 32.4 V |
Overvoltage Protection Type | Shut down o/p voltage, re-power on to recover |
Environmental |
|
Operating Temperature | -30° to +75°C |
Operating Humidity | 20 to 90% RH (non-condensing) |
Temperature Coefficient | ±0.03%/°C (0° to 50°C) |
Vibration | 10 to 500 Hz, 2G 10 min./1 cycle (period for 60 min. each along X, Y, Z axes) |