AeroX Stream 200
AeroX Stream 200
OrderableAWOS Field-Ready System
Pricing
Request a quote Have pricing access? Sign in
Configuration
- 120Vac Mains Power, w/o Heater, w/o SDM-SIO4A45224-120-NH-0SD-CH2
- 120Vac Mains Power, w/o Heater, w/2 SDM-SIO4A45224-120-NH-2SD-CH2
- 120Vac Mains Power, w/120V Heater, w/o SDM-SIO4A45224-120-H1-0SD-CH2
- 120Vac Mains Power, w/120V Heater, w/2 SDM-SIO4A45224-120-H1-2SD-CH2
- 240Vac Mains Power, w/o Heater, w/o SDM-SIO4A45224-240-NH-0SD-CH2
- 240Vac Mains Power, w/o Heater, w/2 SDM-SIO4A45224-240-NH-2SD-CH2
- 240Vac Mains Power, w/240V Heater, w/o SDM-SIO4A45224-240-H2-0SD-CH2
- 240Vac Mains Power, w/240V Heater, w/2 SDM-SIO4A45224-240-H2-2SD-CH2
Select a configuration to add to your quote
- Model:
- AeroX Stream 200
- Item Number:
- 45224
- Warranty:
- 1 year
Overview
For an Automated Weather Observing System (AWOS), the Field Data Collection Unit (FDCU) serves as a critical juncture between the sensors out in the field and the data processing unit (DPU). Thus, the FDCU, named AeroX™Stream 200, collects all the data from the various meteorological sensors and sends the data to the DPU for processing and distribution. Furthermore, the AeroX Stream 200 manages the power distribution to each of these sensors and provides a battery backup in the event that the mains power goes out.
Components of the AeroX Stream 200 include a stainless-steel enclosure, data logger, AC to DC power supply, backup battery, transient protection, circuit breakers, maintenance port, barometer(s), data communications, and optional heating. The AeroX Stream 200 is built predominantly of commercial-off-the-shelf (COTS) components, and many of the components are attached via a DIN rail or on the gridded backplate for ease of manufacturing, maintenance, and service.
With the Campbell Scientific data logger at its core, the AeroX Stream 200 has the flexibility and capacity to add both analog and serial sensors that are new or provided by other manufacturers. This sensor flexibility facilitates platform expansion if needs or budgets change.
Learn more about our CampbellAero™ Automated Weather Observing System (AWOS) Solution and our CampbellAero Software.
Key Advantages
Accommodates a variety of sensors, communication peripherals, and power options for reliability in extreme conditions
Technical Description
Power is provided from a 110 to 240 Vac, 45 to 65 Hz, single-phase power source. This AC power flows through a series of transient and surge protections to a 24 Vdc power supply that distributes power to the sensors, communication peripherals, data logger, and battery. These different levels of transient protection defend the system against lightning strikes and unexpected power surges. In the event that the airport’s mains power goes down, the AeroX Stream 200 contains an uninterruptable power supply (UPS) system that can provide three to six hours of backup power, depending on sensor and communication configuration. This estimate is based on a full serial sensor load (12 to 13) with no heaters. For many applications, this full load will not be used, and the backup power will be longer.
Benefits
- Reliable design with the proven CR1000Xe datalogger at its core
- Sensor agnostic on a flexible platform that incorporates commercial-off-the-shelf (COTS) parts
- Versatile to be paired with a variety of communication modules, such as fiber optic, spread-spectrum radio, VHF/UHF radio, serial (RS-232 or RS-484), or Ethernet
- Various configurations to ensure reliable operations globally
- Rugged and weather-resistant stainless-steel enclosure
- Simple manufacturing, service, and maintenance that uses DIN rail and diamond plate mounting for easy parts replacement and future upgrades
- Integrated laptop shelf for field service and calibration equipment
- Optional 400 W enclosure heater for cold climates
Specifications
- Enclosure Classification
- NEMA Type 3R, 4X, 12, and 13
- Enclosure Material
- Stainless steel
- Input Power
- 110 to 240 Vac, 45 to 65 Hz, single phase
- Serial Inputs
- Up to 10 with standard configurations
- Analog Inputs
- 16 single-ended or 8 differential
(individually configured)
Two analog inputs can measure 4 to 20 mA or 0 to 20 mA natively.Four analog inputs can provide pulse/digital I/O functions. - Pulse Inputs
- 10
(P1 to P2 and C1 to C8)
- Voltage Excitation Terminals
- 4
(VX1 to VX4)
- Enclosure Compliance
- CE certification2014/30EU EMC directiveEN 61326-1:2013
- Enclosure Dimensions
- 61 x 76 x 20 cm
(24 x 30 x 8 in.)
Replacement Parts
(18)SDM-SIO4A
Four-Channel Serial I/O Module
The SDM-SIO4A is a serial I/O expansion module for Campbell Scientific data loggers. It is designed to add four additional and individually configurable and addressable RS-232, RS-422, or RS-485 (half- or full-duplex) serial ports to an SDM-capable data logger for the purposes of interfacing with intelligent sensors, actuators, or displays. Up to three SDM-SIO4A modules can be connected to a single data logger SDM port. The SDM-SIO4A channels behave much like a native data logger serial port and use the same familiar serial I/O commands. The SDM-SIO4A is transient and surge protected to IEC61000-4-5 level 4 on the serial port interfaces, avoiding the need for separate transient protection in most applications.
Orderable28518
AC/DC 24 Vdc 20 A Power Adapter with Universal Inputs
The 28518 power supply adapter is DIN rail mountable with selective fuse breaking. It has a single-phase input (85 to 264 Vac) and outputs 24 Vdc at 20 A. To increase a high level of system availability, the unit features preventive function monitoring, whereby it is capable of reporting critical operating states before errors occur.
Orderable8054
12 V 12 Ah Battery without Cable
The 8054 is a rechargeable, 12 V, 12 Ah battery.
Orderable39354
120 Vac 400 W Fan Heater
The 39354 fan heater prevents the formation of condensation and provides an even temperature distribution inside the enclosure. The heater features a PTC temperature-limiting resistor as a heating element to warm an enclosure in colder temperatures. The 39354 also features a touch-safe plastic housing (UL 94V-0) and fixed set-point thermostat. The heater has a class II (double insulated), IP20 protection class and type, respectively.
Orderable39355
240 Vac 400 W Fan Heater
The 39355 fan heater prevents the formation of condensation and provides an even temperature distribution inside the enclosure. The heater features a PTC temperature-limiting resistor as a heating element to warm an enclosure in colder temperatures. The 39355 also features a touch-safe plastic housing (UL 94V-0) and fixed set-point thermostat. The heater has a class II (double insulated), IP20 protection class and type, respectively.
OrderableCH201
12 V Charging Regulator
The CH201 is a microcontroller-based smart charge controller that is ideal for charging 12 Vdc VRLA batteries. The charger uses MPPT (maximum power point tracking) technology to safely manage amperage and voltage for optimal battery charging and longevity. It has dual inputs for use with a solar panel and/or any 15 to 50 Vdc charging source. The dual inputs provide the option for fail-safe charging. The CH201 also outputs various parameters to allow close monitoring of the battery and power usage via RS-232 or SDI-12.
Orderable39167
AC Line Filter, Single-Phase DIN Rail Mount
The 39167 is a double-stage, single-phase filter and is DIN rail mountable. This filter provides protection against interference voltage from the mains power, as well as providing overcurrent and over voltage protection to the system.
Orderable39201
Replacement Surge Protection Plug for 120 Vac Systems
The 39201 is a UL-recognized type 1 and IEC type 2 surge protection plug with a varistor and thermal disconnect. This plug is used with the Phoenix Contact VAL base elements as the L-N replacement plug for 120 Vac systems. The plug has a mechanical and visual fault warning.
Orderable39202
Replacement Surge Protection Plug for 240 Vac Systems
The 39202 is a UL-recognized type 1 and IEC type 2 surge protection plug with a varistor and thermal disconnect. This plug is used with the Phoenix Contact VAL base elements as the L-N replacement plug for 240 Vac systems. The plug has a mechanical and visual fault warning.
Orderable39203
Replacement Surge Protection Plug for 120 or 240 Vac Systems
The 39203 is a UL-recognized type 1 and IEC type 2 surge protection plug with a gas discharge tube and thermal disconnect. This plug is used with the Phoenix Contact VAL base elements as the N-PE replacement plug for both 120 and 240 Vac systems. The plug has a mechanical and visual fault warning.
Orderable31363
Cable Entry Seal with Flat Gasket and Nut
The 31363 is the cable entry seal. If it becomes lost or damaged, the 31363 can be ordered as a replacement.
Orderable39044
Cable Entry Seal with Flat Gasket and Nut
The 39044 is an IP68/NEMA 4X/6P-rated self-locking waterproof cable entry seal/cord grip. The 39044 is UL 94V-2 and RACH certified, as well as RoHS compliant.
Orderable7363
Enclosure Supply Kit, Standard Size
The enclosure supply kit is included with our enclosures, but it can be purchased separately. The assembled equipment aids in mounting your equipment inside the enclosure, as well as monitoring relative humidity and sealing the enclosure. It includes desiccant packs, humidity indicator card, cable ties, putty, screws, grommets, PVC plug, and a Phillips-head screwdriver.
Orderable42815
Four-Unit Desiccant Bags (quantity of 10)
Orderable29137
3 oz Bottle of Replacement Desiccant
The 29137 is replacement desiccant for the desiccant tubes included with the CS451, CS456, CS450, and CS455 pressure transducers, as well as the AeroX Stream 200. It provides enough desiccant to fill the tube approximately 2.5 times. The 29137 desiccant has a cobalt-free indicator that is orange and turns green when saturated.
Orderable39308
Stainless-Steel Tower Mounting Kit for AeroX Stream 200
The 39308 is the tower mounting kit used to attach the AeroX™Stream 200 AWOS Field-Ready System to a Millard frangible tower. The kit comprises two 609.6 mm (24.0 in.) stainless-steel brackets for mounting the AeroX Stream 200 to a Millard tower or similar lattice-style tower with 12.7 mm (0.5 in.) diameter pipe. It is constructed of a Unistrut profile with stainless-steel clamps. The struts have M8 threaded studs and come with all the necessary hardware to mount the AeroX Stream 200 to the tower.
Orderable39356
Grounding Hardware Kit for AeroX Stream 200
The 39356 kit contains all the necessary hardware to ground the AeroX™Stream 200 enclosure to the tower, including a clamp to attach to the tower and a 406.4 mm (16.0 in.) braided stainless-steel cable.
Orderable39421
R. M. Young Pressure Port with Offset Bracket
The 39421 provides an effective static pressure inlet for a barometric pressure sensor. Ambient wind of 20 m/s (44.7 mph) blowing over a typical barometer inlet tube can cause pressure errors as great as 3 hPa. This pressure port minimizes these errors using its unique parallel plate design, which effectively slows air velocity at the pressure inlet. In addition, the simple internal baffle system creates a barrier to water and snow intrusion into the barometer.
Orderable
Need Something Not Listed?
(45224)Don't see what you need from among these options? Download the complete configuration list below.
View all product configurationsCompatibility
- The AeroX Stream 200 is backwards compatible with legacy Coastal Environmental Systems (CES) Aviation Intercept software.
- The AeroX Stream 200 works with both 120 Vac and 240 Vac mains power.
- The AeroX Stream 200 enclosure is not type certified for offshore oil platforms. Please contact Campbell Scientific for suitable options.