CS100-QD
CS100-QD
RetiredBarometer for RAWS Enclosures
No longer available to order
This product is retained for service, documentation, and compatibility information.
- Model:
- CS100-QD
- Item Number:
- 18832
- Warranty:
- 3 years
Overview
The CS100-QD barometer, manufactured by Setra, measures for a standard barometric pressure range of 600 to 1100 hPa (mBar), which is approximately sea level to 12,000 feet. It is mounted inside a RAWS-F or RAWS-P enclosure and wired to the CR1000 wiring panel.
Key Advantages
Compatible with RAWS-P and RAWS-F stations
Technical Description
The CS100-QD is a Campbell Scientific version of Setra's model 278 barometer. It uses Setra’s Setraceram capacitive sensor and IC analog circuit to measure barometric pressure.
The CS100-QD is encased in a stainless steel and polyester case fitted with an 1/8 in. barbed fitting for pressure connection. It includes an internal switching circuit that allows the data logger to power the barometer only during measurement, which reduces power consumption.
Specifications
- Pressure Range
- 600 to 1100 hPa (mBar)
- Accuracy at 20°C
- ±0.5 mb
- Accuracy at 0° to 40°C
- ±1.0 mb
- Accuracy at -20° to +50°C
- ±1.5 mb
- Accuracy at -40° to +60°C
- ±2.0 mb
- Linearity
- ±0.4 mb
- Hysteresis
- ±0.05 mb
- Repeatability
- ±0.03 mb
- Resolution
- ±0.01 mb
- Long-Term Stability
- ±0.1 mb per year
- Response Time
- < 100 ms
- Excitation
- 9.5 to 28 Vdc
- Current Consumption
- < 3 mA
(active)
< 1 µΑ(sleep mode)
- Warm-up Time
- < 1 s
- Operating Temperature
- -40° to +60°C
- Cable Diameter
- 0.8 cm
(0.3 in.)
- Cable Length
- 0.8 m
(2.5 ft)
- Dimensions
- 9.1 x 6.1 x 2.5 cm
(3.6 x 2.4 x 1.0 in.)
- Weight
- 135 g
(4.8 oz)
Replacement Parts
(3)16004
Replacement Terminal Block for Barometers
This terminal block plugs into the CS100 to provide connection terminals for the sensor leads coming from the datalogger.
Orderable505
Screw #6-32 x .375 Pan Phillips
These screws, along with the 6044 grommets, are commonly used together to secure our equipment to the backplates of our enclosures.
Orderable6044
Grommet for #6 or #8 Screw
These grommets are commonly used with the 505 screws to secure our equipment to the backplates of our enclosures.
Orderable
Ships With
(3)- NIST Traceable & ANCI/NCSL Z540-1-1994 Calibration Certificate
505
Screw #6-32 x .375 Pan Phillips
OrderableQty 26044
Grommet for #6 or #8 Screw
OrderableQty 2
Compatibility
The CS100-QD barometer is mounted inside of a RAWS-F or RAWS-P enclosure and wired to the CR1000 wiring panel.