FREEWAVE 900 MHz, 1 W Spread Spectrum Radio with Ethernet
Overview
The FGR-115RE provided a transmission range of up to 60 miles (please note that line-of-sight obstructions, RF interference, and antenna type affected transmission distance). The FGR-115RE had a 10baseT Ethernet connector making it an ideal base station radio/modem when data needed to be transmitted over a local area network or the Internet. The FGR-115RE could also serve as a stand-alone repeater radio/modem. Campbell Scientific did not recommend using the FGR-115RE at the field site because it did not have an RS-232 connector. Either an NL100 or NL115 was required to connect it to a data logger.
Technical Description
The FGR-115RE had a 10baseT Ethernet connector making it an ideal base station radio/modem when data needed to be transmitted over a local area network or the Internet. Campbell Scientific did not recommend using the FGR-115RE at the field site because it did not have an RS-232 connector. Either an NL100 or NL115 was required to connect it to a data logger.
The FGR-115RE radio spread the normally narrowband information signal over a relatively wide band of frequencies. This process made communications more immune to noise and interference from RF sources such as pagers, cellular phones, and multi-path. User-selectable frequency hopping patterns reduced the radio's susceptibility to RF interference from other spread spectrum devices.
The FGR-115RE was retired on 12 June 2007.
Specifications
- Operating Frequency
- 902 to 928 MHz
- Type
- Frequency Hopping Spread Spectrum (FHSS) Transceiver
- Modulation
- GFSK, 115.2 kbps or 153.6 kbps
- Hopping Bands
- 7, user selectable
- Hopping Channels
- 50 to 112, user selectable
- Frequency Hopping Patterns
- 15 per band, 105 total, user selectable
- Occupied Bandwidth
- 230 kHz
- Transmitter Power Output
- 100 mW to 1 W
(+30 dBm)
- Antenna Connector
- Type N Female
- Receiver Sensitivity
- -108 dBm
(for 10-6 BER)
-110 dBm(for 10-4 BER)
- Operating Temperature Range
- -40° to +75°C
- Power
- 6 to 30 Vdc
- Maximum Throughput
- 100 kbps
- Data Interface Connector
- RJ45
- Dimensions
- 16.5 x 7.4 x 5.7 cm
(6.5 x 2.9 x 2.2 in.)
- Weight
- 441 g
(15.5 oz)
Average Current Drain
- Idle
- 70 mA
- Receiving
- 125 mA
- Transmitting
- 550 mA
Other Accessories
(10)
14203
900 MHz 3 dBd Omnidirectional Antenna without Mounting Hardware
The 14203 is 3 dBd gain omnidirectional antenna. It is suitable for base station use where you need to communicate with multiple stations located in different directions. The 14203 is also preferred in mobile applications and in other applications in which the best radio path is not constant, including close-up applications without clear line-of-sight.
The 14203 is suitable for outdoor use and terminates in a Type N Female connector. The 14203 requires the COAXNTN cable to connect it to the radio.Orderable
14201
900 MHz 9 dBd Yagi Antenna with Mounting Hardware
Suitable for the outdoors, this high-gain (9 dBd), directional (Yagi) antenna has a narrow beam width, so precise aiming is mandatory. The 14201 is useful for longer distances and when communicating only with one other station. The antenna's Type N Female connector attaches to one end of a COAXNTN-L cable. The other end of the cable attaches to the radio.
Please note that because the FCC limits EIRP to 36 dBm, use of this antenna may require a reduction of the radio's transmit power.Orderable
14205
900 MHz 6 dBd Yagi Antenna with Mounting Hardware
The 14205 is a high-gain (6 dBd), directional (Yagi) antenna suitable for the outdoors. It transmits for longer distances and communicates with only one other station. The antenna has a Type N Female connector that attaches to the radio via a COAXNTN-L cable.
Please note that because the FCC limits EIRP to 36 dBm, use of this antenna may require a reduction of the radio's transmit power.Orderable
14221
900 MHz 3 dBd Omnidirectional Antenna with Mounting Hardware
The 14221 is the highest gain (3 dBd) omnidirectional antenna available for this radio. It is used outdoors and has a Type N Female connector. The COAXNTN-L cable connects the antenna to the radio.
Orderable
15970
900 MHz 1 dBd Omnidirectional Dipole Antenna with Adhesive Mount
Adhesive backing on this antenna adheres to a wall, rear-view mirror, window, or another suitable flat, non-conductive surface. The 15970 is a 1 dBd antenna that should reside inside a building or enclosure.
Orderable
14204
900 MHz 0 dBd 1/2 Wave Omnidirectional Antenna with RPSMA Connector
Suitable for inside a building or enclosure, this 0 dBd, ½ wave whip antenna is adjustable from 0° to 90°. The antenna has an RPSMA connector that attaches to the radio via the 18686 Adapter.
Orderable
15730
900 MHz 0 dBd 1/4 Wave Omnidirectional Antenna with RPSMA Connector
The 15730 is a unity gain, right angle, whip antenna that should reside inside a building or enclosure. It has an RPSMA connector that attaches to the radio via the 18686 Adapter.
Orderable
18686
Coaxial Adapter, Type N Pin (Male) to RPSMA Socket (Female)
Whip antennas attach to the radio via the 18686 RPSMA Socket (Female)-to-Type N Pin (Male) Adapter.
Orderable
COAXNTN
RG8 Antenna Cable with 2 Type N Pin (Male) Connectors
One end of this low-loss RG8 antenna cable terminates in a Type N pin (male) connector that attaches to a 14203, 14201 or 14221 antenna. The other end terminates in another Type N pin (male) connector that attaches to the radio.
Orderable
31320
Surge Protection Kit, Type N to N, 700 to 2700 MHz
The 31320 is an RF surge protection kit with flange mounting bracket. It may be flange-mounted to an enclosure backplate or bulkhead-mounted through an enclosure wall. One side of the surge protector connects to a radio with a Type N antenna connection. The other side connects to an antenna/antenna coaxial cable with Type N connector.
Orderable
Ships With
(5)- 12 Vdc, 500 mA Wall Charger from original mfg
- Instruction Manual
- Ethernet cable from original mfg
18849
12 Vdc Power Cable for FGR-115RC Radios
20625
RF450 Diagnostics and Programming Cable with Software
Orderable
Compatibility
Communications
The FGR-115RE can be used in networks containing RF450 radios. Campbell Scientific does not recommend using it with our RF401-series or RF430-series radios.
Data Logger Considerations
The FGR-115RE does not have an RS-232 connector, and therefore requires either an NL100 or NL115 to connect it to a data logger. For this reason, Campbell Scientific recommends using it's cousin, the FGR-115RC, at the field site instead of the FGR-115RE.
Product Life Events
- Available for Order
- January 1, 1950
- Retired
- June 12, 2007
- Free Support Until
- March 31, 2018
- End of Life
- March 31, 2018
- Calibration Available Until
- March 31, 2018
- Repair Available Until
- March 31, 2018