Overview
The HMP50 measures both temperature and relative humidity and is suitable for long-term, unattended monitoring. The humidity component features a field-replaceable chip, which eliminates downtime typically required for the recalibration process. The HMP50 is compatible with all Campbell Scientific data loggers.
Technical Description
The HMP50 measures temperature with a 1000 Ohm platinum resistance thermometer (PRT) and relative humidity (RH) with a 50Y Intercap capacitive chip. The chip is field-replaceable, which eliminates the downtime typically required for the recalibration process. This temperature and RH sensor is compatible with all Campbell Scientific data loggers.
The HMP50 should be housed in a solar radiation shield—typically the 41303-5A. The 41303-5A 6-plate naturally aspirated shield attaches to a mast, crossarm, or tower leg.
Product Notes
Benefits
- Field-replaceable humidity chip eliminates recalibration down time
- Can be mounted to a tower/tripod mast or crossarm
Specifications
- Supply Voltage
- 7 to 28 Vdc
(typically powered by data logger’s 12 V supply)
- Current Consumption
- 2 mA
(typical)
- Housing Material
- Chrome-coated aluminum and chrome-coated ABS plastic
- Operating Temperature Range
- -40° to +60°C
- Diameter
- 1.2 cm
(0.47 in.)
- Length
- 7.1 cm
(2.8 in.)
- Weight
- 0.05 kg (0.1 lb) with 1.83-m (6-ft) cable
Relative Humidity
- Sensor
- Vaisala’s INTERCAP capacitive chip
- Measurement Range
- 0 to 98% RH
(non-condensing)
- Accuracy
- ±3%
(0% to 90% range)
±5%(90% to 98% range)
- Temperature Dependence
- See graph in product brochure.
Temperature
- Temperature Sensor
- 1000 ohm Platinum Resistance Thermometer
- Measurement Range
- -40° to +60°C
- Accuracy
- See graph in product brochure.
Accessories
(6)41303-5A
6-Plate Solar Radiation Shield
Orderable41003-5
10-Plate Solar Radiation Shield
Orderable41322
10-Plate Shield Adapter for Use with 107, 108, 109, or HMP60
Orderable6637
Hex Adapter Plug
OrderableRAD06
6-Plate Solar Radiation Shield
OrderableRAD10
10-Plate Solar Radiation Shield for Small Sensors
Orderable
Other Accessories
(6)41303-5A
6-Plate Solar Radiation Shield
The 41303-5A provides a six-plate naturally-aspirated radiation shield that houses one HMP50 probe. Its louvered construction allows air to pass freely through the shield thereby keeping the probe at or near ambient temperature. The 41303-5A attaches to a crossarm, mast, or user-supplied pipe with a 1.0" to 2.1" OD.
Orderable41003-5
10-Plate Solar Radiation Shield
The 41003-5 10-plate radiation shield can be used instead of the 41303-5A six-plate shield, but additional hardware is required (see below).
Orderable41322
10-Plate Shield Adapter for Use with 107, 108, 109, or HMP60
The 41322 adapter plate is used to mount an HMP50 probe in the lower part of a 41003-5 10-plate radiation shield.
Orderable6637
Hex Adapter Plug
The 6637 Hex Adapter Plug can be used to install the HygroVue™10 Digital Temperature and Relative Humidity Sensor in the R. M. Young 41003-5 10-plate or 41005-5 14-plate solar radiation shield. It can also be used with the 41381 extension tube to mount a HMP60, HMP50, or CS500 temperature and relative humidity probe in the higher part of the 41003-5 or UT12VA solar radiation shield.
OrderableRAD06
6-Plate Solar Radiation Shield
When exposed to sunlight, the HMP50-L must be housed in a radiation shield. The RAD06 uses a double-louvered design that offers improved sensor protection from driving rain, snow, and insect intrusion. It also has lower self-heating in bright sunlight combined with higher temperatures (> 24°C (~75°F)) and low wind speeds (< 2m/s (~4.5 mph)), providing a better measurement.
OrderableRAD10
10-Plate Solar Radiation Shield for Small Sensors
When exposed to sunlight, the HMP50-L must be housed in a radiation shield. The RAD10 uses a double-louvered design that offers improved sensor protection from driving rain, snow, and insect intrusion. It also has lower self-heating in bright sunlight combined with higher temperatures (> 24°C (~75°F)) and low wind speeds (< 2m/s (~4.5 mph)), providing a better measurement.
Orderable
Compatibility
Mounting
The HMP50 is typically housed in a 41303-5A 6-plate naturally aspirated shield.
It may also be housed in a 41003-5 10-plate shield if additional hardware is used. A 41322 Adapter Plate allows the HMP50 to be mounted in the lower part of the 41003-5 10-plate shield. Alternatively, a 41381 extension tube and the 6637 split nut plug can be used to mount the HMP50 in a higher part of the 41003-5; the #41381 cable is also required.
Both the 41303-5A and the 41003-5 attach to a crossarm, mast, or user-supplied pipe with a 1.0-in. to 2.1-in. outer diameter.
Related Resources
Case Studies

District of Columbia: Solar Decathlon
Evaluating performance in efficient home competition
National Mall, Washington, D.C.
May 14, 2009
View
Texas: College Weather Station
Weather and climate in North Texas
Texas, USA
January 18, 2018
View
South Africa: Solar Prospecting
Assessing solar energy resources
Botswana and Lesotho, South Africa
April 17, 2015
View
Israel: Marine Meteorology on the Red Sea
Meteorological and oceanographic monitoring of conditions in the Gulf of Eilat
Israel, Red Sea
March 15, 2011
View
Documents
Services Available
- Repair
- No
- Calibration
- No
- Free Support