CR23X

Micrologger for Data Acquisition
CR23X

CR23X

End of life

Micrologger for Data Acquisition

No longer available to order

This product is retained for service, documentation, and compatibility information.

Replaced by

  • CR3000

    Measurement and Control Datalogger

Model:
CR23X
Item Number:
CR23X

Overview

The CR23X Micrologger® was a portable, self-contained package that could store over 1,000,000 data points. It consisted of measurement and control electronics, communication ports, keyboard, 2-line alphanumeric display, power supply, and a battery-backed clock. The CR23X measured most sensor types directly, communicated via modems, reduced data, controlled external devices, and stored both data and programs in either non-volatile Flash memory or battery-backed SRAM.

Technical Description

The CR23X is a self-contained, rugged data logger that can measure most sensor types directly, communicate via modems, reduce data, control external devices, and store both data and programs in either non-volatile Flash memory or battery-backed SRAM.

The CR23X has an integral, 2-line, alphanumeric display and power supply. A battery-backed, real-time clock and 2M of nonvolatile data storage is included. The CR23Xs are available with a sealed rechargeable battery base, an alkaline base, or in a low-profile version without batteries.

Benefits

  • Compact, self-contained data logger
  • Stores 1,000,000 data points (nonvolatile)
  • Data format options are mixed array (default) or table

Specifications

-NOTE-
Note: Additional specifications are listed in the CR23X Specifications Sheet.
Analog Inputs
24 single-ended or 12 differential, individually configured
Pulse Counters
4
Switched Voltage Excitations
4
Control/Digital I/O Ports
8
Continuous Analog Outputs
2
Serial I/O Port (CS I/O)
1
RS-232 Port
1
Scan Rate
100 Hz
Burst Mode
1500 Hz
Analog Voltage Resolution
To 0.33 uV
A/D Bits
15
Programming
Edlog
Data Storage
Mixed Array, Table
Telecommunications
Standard, Modbus, Alert
Standard Operating Temperature Range
-25° to +50°C
Extended Operating Temperature Range
-40° to +80°C
Corrected Display Temperature
-20° to +40°C
Survival Display Temperature
-40° to +85°C

Replacement Parts

(13)

Compatibility

A typical field-based CR23X system consisted of:

  • CR23X Micrologger with specified Operating System and Alkaline, Rechargeable, or User-Supplied Power Supply
  • Weatherproof Enclosure
  • Communications Peripheral(s)
  • Programming and Communications Software
  • Sensors
  • Data retrieval peripherals

Related Resources

Services Available

Repair
No
Calibration
No
Free Support
No