CS106
CS106
OrderableBarometer
Configuration
- w/Ferrules on WiresCS106-PFPart Number: 39380
- w/Tinned WiresCS106-PTPart Number: 20657
Select a configuration to add to your quote
- Model:
- CS106
- Item Number:
- CS106
- Warranty:
- 3 years
Overview
The CS106, manufactured by Vaisala, measures barometric pressure for the range of 500 to 1100 hPa (mBar). This range equates to from below sea level (as in a mine) to over 15,000 feet above sea level. Designed for use in environmental applications, the CS106 is compatible with most Campbell Scientific data loggers. The CS106 has an attached 76.2 cm (30 in.) cable.
Key Advantages
Resides inside weatherproof enclosure
Technical Description
The CS106 uses Vaisala’s BAROCAP silicon capacitive sensor to measure barometric pressure. It is encased in a plastic shell (ABS/PC blend) fitted with an intake valve for pressure equilibration.
The CS106 outputs a linear signal of 0 to 2.5 Vdc, which allows the barometer to be directly connected to a Campbell Scientific data logger. An internal switching circuit allows the data logger to power the CS106 only during measurement, which reduces power consumption.
Benefits
- Optimized to mount in Campbell Scientific enclosures
- Integral switching circuit limits power consumption to measurement cycle
- Three-year warranty
Specifications
- -NOTE-
- 1 hPa = 1 mBar
- Pressure Range
- 500 to 1100 hPa
- Long-Term Stability
- ± 0.1 hPa per year
- Settling Time
- 1 s to reach full accuracy after power-up
- Response Time
- 500 ms to reach full accuracy after a pressure step
- Resolution
- ±0.01 hPa
- Output Voltage
- 0 to 2.5 Vdc
- Supply Voltage
- 10 to 30 Vdc
- Elevation
- ~609.6 m (2,000 ft) below sea level (as in a mine) to 4,572 m (15,000 ft) above sea level
- Accuracy
- Accuracy refers to the root sum squared (RSS) of end point non-linearity, hysteresis, repeatability, and calibration uncertainty.±0.3 hPa
(@ +20°C)
±0.6 hPa(@ 0° to 40°C)
±1.0 hPa(@ -20° to +45°C)
±1.5 hPa(@ -40° to +60°C)
- Linearity
- ±0.25 hPa
- Hysteresis
- ±0.03 hPa
- Repeatability
- ±0.03 hPa
- Calibration Uncertainty
- ±0.15 hPa
- Current Consumption
- < 4 mA
(active)
< 1 µΑ(quiescent)
- Temperature Range
- -40° to +60°C
- Dimensions
- 6.8 x 9.7 x 2.8 cm
(2.7 x 3.8 x 1.1 in.)
- Cable Length
- 76.2 cm
(30 in.)
- Weight
- 90 g
(3.2 oz)
Common Accessories
(3)
CABLE5CBL
5-Conductor 22 AWG Cable with Drain
The CABLE5CBL is used when the barometer and datalogger are housed in different enclosures. This 22 AWG, five-conductor cable has a Santoprene jacket and an aluminum Mylar shield.
Orderable
ENC100
Barometer Enclosure
The ENC100 is available for housing the barometer in its own enclosure. It includes a backplate, compression fitting, vent, and mounting bracket.
Orderable
39130
DIN Rail Terminal Kit with 2 Terminals and 6 Wires
The 39130 provides the needed DIN rail terminals, separator, and wires to connect any product to a data logger or other peripheral that requires six wires for connection. This kit provides the following wires: black, light blue, green, red, yellow, and clear. The color-coding of these wires matches the wire coloring of the product for ease in connection, maintenance, and troubleshooting.
Orderable
Replacement Parts
(3)
16004
Replacement Terminal Block for Barometers
This terminal block plugs into the CS106 to provide connection terminals for the sensor leads coming from the datalogger.
Orderable
6044
Grommet for #6 or #8 Screw
These grommets are commonly used with the 505 screws to secure our equipment to the backplates of our enclosures.
Orderable
505
Screw #6-32 x .375 Pan Phillips
These screws, along with the 6044 grommets, are commonly used together to secure our equipment to the backplates of our enclosures.
Orderable
Ships With
(4)
505
Screw #6-32 x .375 Pan Phillips
OrderableQty 2
6044
Grommet for #6 or #8 Screw
OrderableQty 2- Sensor cable, 2.5 ft
- NIST Traceable Calibration Certificate
Similar Products
(1)Compatibility
Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.
Data Logger Considerations
A 2.5-ft cable is supplied with the sensor for connection to the data logger. The cable connects to a control port, single-ended analog input terminal, 12 V power terminal, and ground terminal on the data logger.
Mounting
The CS106 is typically mounted next to the data logger inside an ENC12/14 or larger enclosure. The very small ENC100 is available for housing the CS106 separately, in its own enclosure.
Compatible Products
(8)
CR6
High-Capacity Data Acquisition System
OrderableNotes—
CR300
Measurement and Control Datalogger
RetiredNotes—
CR310
Measurement and Control Datalogger
OrderableNotes—
CR350
Measurement and Control Datalogger
OrderableNotes—
CR800
Measurement and Control Datalogger
RetiredNotes—
CR850
Measurement and Control Datalogger
RetiredNotes—
CR1000
Measurement and Control Datalogger
RetiredNotes—
CR3000
Measurement and Control Datalogger
RetiredNotes—
Related Resources
Case Studies

Utah Energy Industry: Air Quality and Met Monitoring
Recording baseline air quality and meteorological data at proposed power plant sites
Utah, USA
August 7, 2009
View
Argentina: SCADA System for Agricultural Regions
Monitoring growing conditions in different agricultural regions of a large country
West central Argentina
May 11, 2010
View
Peru: High-Elevation Weather on Glaciers
Glacier monitoring
Andes Mountains, Peru
March 25, 2015
View
Union of the Comoros: Establishment of Four Weather Stations for Better Resilience to Climatic Hazards
Monitoring an area prone to seasonal cyclones
The Union of the Comoros, East Africa
January 14, 2022
View
Showing 4 of 5 results
See all Case StudiesDocuments
Product Life Events
- Available for Order
- July 7, 2007