ENC8/10
ENC8/10
OrderableWeather-Resistant Enclosure, 8 x 10 inches
Pricing
Configuration
Sign in for option pricing- 1 Conduit for Cables No Enclosure Mounting w/o Surge Protection HoleENC8/10-SC-NM-NAPart Number: 45235-SC-NM-NA
- 1 Conduit for Cables Tripod Mast Mounting w/o Surge Protection HoleENC8/10-SC-MM-NAPart Number: 45235-SC-MM-NA
- No Conduit/Entry Seal Tripod Mast Mounting w/o Surge Protection HoleENC8/10-NC-MM-NAPart Number: 45235-NC-MM-NA
- No Conduit/Entry Seal No Enclosure Mounting w/o Surge Protection HoleENC8/10-NC-NM-NAPart Number: 45235-NC-NM-NA
- 6 Entry Seals for Cables No Enclosure Mounting w/o Surge Protection HoleENC8/10-6ES-NM-NAPart Number: 45235-6ES-NM-NA
- 6 Entry Seals for Cables Tripod Mast Mounting w/o Surge Protection HoleENC8/10-6ES-MM-NAPart Number: 45235-6ES-MM-NA
Select a configuration to add to your quote
- Model:
- ENC8/10
- Item Number:
- 45235
- Warranty:
- 1 year
Overview
The ENC8/10 is a weather-resistant enclosure that is 8 inches wide and 10 inches tall. It is the smallest of our standard enclosures, yet it is extra deep with a depth of 6 inches. This enclosure is suitable for use with CR300-series or CR200X-series dataloggers. The ENC8/10 can house one of these data loggers and a small power supply. Alternatively, this enclosure can be used to mount a communication or measurement peripheral without a data logger.
Please note that a grounding wire is not included with the enclosure.
Technical Description
The ENC8/10's backplate is prepunched with half-inch-on-center holes.
Specifications
- Color
- White
(Reflects solar radiation, reducing temperature gradients inside the enclosure without using a separate radiation shield.)
- Enclosure Classification
- NEMA 4X
(before being modified for cable entry, conduit, or ground lug)
- Construction
- Fiberglass-reinforced polyester enclosure with door gasket, external grounding lug, stainless-steel hinge, and lockable hasps
- Number of Cable-Entry Seals
- 6 small
- Dimensions
- 24,8 x 19.7 x 15.9 cm
(9.7 x 7.7 x 6.3 in.) internal
30.4 x 23.9 x 16.5 cm(12.0 x 9.4 x 6.5 in.) external
- Weight
- 2.36 kg
(5.2 lb)
Common Accessories
(2)32464
User-Installed Desiccant Holder
The 32464 accommodates one package of the 4905 4-unit desiccant bags. This holder has adhesive Velcro strips (supplied) that the customer uses to mount it to the inside lid of a Campbell Scientific enclosure.
OrderableCS211
Smart Enclosure Sensor
The CS211 is a low-power, smart sensor designed to monitor temperature and humidity levels inside enclosures. The sensor features an optical door switch to detect door openings and closings, and a multifunctional button that recognizes short, long, and double presses for user-defined actions. Additionally, the CS211 includes an LED indicator to signal enclosure wetness and when desiccant needs to be replaced.
Orderable
Replacement Parts
(15)28878
Replacement Enclosure Humidity Indicator Card
The 28878 is a replacement humidity indicator card. It provides a visual reference of humidity level inside the enclosure. Colored circles change color from blue to pink to indicate levels of 30%, 40%, and 50% relative humidity. Double sticky tape on the back of the card allows it to be easily secured to an enclosure lid.
Orderable32415
Universal Backplate for ENC8/10
The 32415 Universal Backplate is available as a replacement part for ENC8/10 enclosures. The backplate is completely prepunched with a matrix of holes.
Orderable42815
Four-Unit Desiccant Bags (quantity of 10)
The 42815 includes 10 large, four-unit desiccant bags, used to absorb humidity within enclosures. Multiple packs are recommended for customers who need to desiccate multiple enclosures or systems.
Orderable32477
Enclosure Supply Kit, Small Size
The 32477 includes desiccant packs, humidity indicator card, cable ties, putty, screws, grommets, PVC plug, and a Phillips-head screwdriver.
Orderable8267
Screw #10-32 x .312 Flat Phillips
The 8267 screw is used to attach a backplate to the inside of the ENC8/10 enclosure. This flat screw allows for the maximum amount of space on the backplate to be used for mounting.
Orderable5449
Enclosure Ground Lug
The 5449 may be purchased to replace the ground lug attached to the enclosure. This enclosure ground lug is required to properly ground the enclosure.
Orderable23
Stainless-Steel Nut #10-32
This stainless-steel nut may be purchased to replace a lost or damaged nut.
Orderable25746
1-1/2 PVC Coupling PVC Female Adapter
The 25746 and 25744 are the two parts used to create the standard conduit for Campbell Scientific enclosures. If a portion of the conduit for an ENC or PWENC enclosure becomes lost, the 25746 and 25744 can be ordered as replacements.
Orderable25744
1-1/2 Panel Bushing Pin (Male)
The 25744 and 25746 are the two parts used to create the standard conduit for Campbell Scientific enclosures. If a portion of the conduit for an ENC or PWENC enclosure becomes lost, the 25744 and 25746 can be ordered as replacements.
Orderable31363
Cable Entry Seal with Flat Gasket and Nut
The 31363 is the cable entry seal used on the ENC8/10-ES option. If a part becomes lost, the 31363 can be ordered as a replacement.
Orderable6688
Plug for Cable Entry Connector
The 6688 is the plug that fits inside the 31363 Cable Entry Seal when there is not a cable running through it. The 6688 can be ordered to replace a lost plug.
Orderable25745
PVC Conduit 1.5 in. to 0.5 in. Reducer
The 25745 is used to reduce the size of the conduit opening when only a couple of wires are threaded through. With the reducer, there is a smaller opening that needs to be filled with putty to seal.
Orderable32430
ENC8/10 Mast and Pole Mounting Kit
The 32430 can be ordered to replace damaged mounting kit parts.
Orderable5725
14 AWG Enclosure Ground Wire, 24 in. long
This 14 gauge ground wire connects the enclosure ground lug to the datalogger.
Orderable3890
Silicone O-Ring
The 3890 is a silicone O-ring used. Customers will periodically need to replace worn-out O-rings.
Orderable
Need Something Not Listed?
(45235)Don't see what you need from among these options? Download the complete configuration list below.
View all product configurationsShips With
(1)Similar Products
(5)Compatibility
Inside the Enclosure
The following products will NOT fit inside the ENC8/10: CR3000, 21X, CR23X, CR5000, CR9000X, CR9000, CR7X, 27207, 28517, 31143, SDM-CD16AC, SDM8X50, CFM1, NL116, NL121, BP24, and BP84.
A CR1000 with a device connected to the peripheral port will NOT fit inside the ENC8/10. A CR1000 with a BP7, ALK7, BPALK, PS150, or PS200 will NOT fit inside the ENC8/10. A CR1000 by itself, however, will fit inside the enclosure when it is installed vertically rather than horizontally.
The following products will fit inside the ENC8/10 if they are installed vertically rather than horizontally: CR6, CR800, CR850, CR1000, PS150, PS200, AM25T, AM16/32B, SDM-CAN, SDM-CD16D, SDM-CD16S, SDM-CVO4, SDM-IO16, CDM-A108, CDM-A116, CDM-V300, CDM-V305, LR4, TDR100, and 28532.
The TX321 and HUGHES9502 will fit inside the ENC8/10, and there may be enough room for a small data logger as well, but there will not be enough room for a power supply/battery as well.
The following products will fit inside the ENC8/10: CR300-series, CR200X-series, ALK7, BP7, BP12, BPALK, A21REL-12, A300, A547, A6REL-12, AL200, AVW200-series, CE4, CE8, CH150, CH200, CM320, COM220, CS100, CS106, CWB100-series, DCDC18R, FC100, HUB-CPI, LLAC4, MD485, NL240, QD1, RAVENXTV, RF310, RF321, RF322, RF323, RF401A, RF407, RF412, RF422, RF451, RF500M, RV50, SC32B, SC932A, SC932C, SC-CPI, SDM-AO4A, SDM-INT8, SDM-SW8A, SDS122, SRM-5A, ST-21, 25458, and 31551.
Mounting
The ENC8/10 can be mounted to a pipe with a minimum size of 0.5 in. (0.840 OD). The maximum pipe size is 2.0 in. (2.375 OD) or up to a 2.4 in. OD tube.