ENC14/16
ENC14/16
OrderableWeather-Resistant Enclosure, 14 x 16 inches
Pricing
Configuration
Sign in for option pricing- 2 Conduits for Cables Tripod Mast Mounting No Desiccant/Doc Holder w/o Surge Protection Hole No Door Open Indicator45228-DC-MM-NA-NA-NA
- 2 Conduits for Cables No Enclosure Mounting No Desiccant/Doc Holder w/o Surge Protection Hole No Door Open Indicator45228-DC-NM-NA-NA-NA
- 2 Conduits for Cables 4-10 Inch Pole Mounting No Desiccant/Doc Holder w/o Surge Protection Hole No Door Open Indicator45228-DC-PM-NA-NA-NA
- 2 Conduits for Cables Tower Mounting No Desiccant/Doc Holder w/o Surge Protection Hole No Door Open Indicator45228-DC-TM-NA-NA-NA
- No Conduit/Entry Seal Tripod Mast Mounting No Desiccant/Doc Holder w/o Surge Protection Hole No Door Open Indicator45228-NC-MM-NA-NA-NA
- No Conduit/Entry Seal No Enclosure Mounting No Desiccant/Doc Holder w/o Surge Protection Hole No Door Open Indicator45228-NC-NM-NA-NA-NA
- No Conduit/Entry Seal 4-10 Inch Pole Mounting No Desiccant/Doc Holder w/o Surge Protection Hole No Door Open Indicator45228-NC-PM-NA-NA-NA
- No Conduit/Entry Seal Tower Mounting No Desiccant/Doc Holder w/o Surge Protection Hole No Door Open Indicator45228-NC-TM-NA-NA-NA
- 1 Conduit for Cables Tripod Mast Mounting No Desiccant/Doc Holder w/o Surge Protection Hole No Door Open Indicator45228-SC-MM-NA-NA-NA
- 1 Conduit for Cables No Enclosure Mounting No Desiccant/Doc Holder w/o Surge Protection Hole No Door Open Indicator45228-SC-NM-NA-NA-NA
Select a configuration to add to your quote
- Model:
- ENC14/16
- Item Number:
- 45228
- Warranty:
- 1 year
Overview
The ENC14/16 is a weather-resistant enclosure that is 14 in. wide and 16 in. tall. This medium-large enclosure can house a data logger, a power supply, and one or more peripheral—depending on the size of the peripherals. A common use for the ENC14/16 is to mount a larger enclosure to the leg base of a CM110, CM115, or CM120 tripod, because the larger ENC16/18 cannot be mounted to the leg base of these tripods.
Please note that a grounding wire is not included with the enclosure.
Key Advantages
Campbell components mount easily and securely
Technical Description
The ENC14/16's backplate is prepunched with half-inch-on-center holes suitable for attaching a data logger, power supply, and a communications or measurement and control peripheral.
This enclosure is shipped with the 7363 enclosure supply kit that consists of desiccant, a humidity indicator card, cable ties, wire tie tabs, putty, grommets, screws, and PVC coupling. Additionally, Campbell Scientific offers a CS210 Enclosure Humidity Sensor for monitoring relative humidity inside of the enclosure. (See Ordering Info on the web page.)
Benefits
- Weather resistant to protect instruments
- Backplate designed so that Campbell Scientific components mount easily and securely
- White, UV-stabilized enclosure reflects solar radiation—reducing temperature gradients inside the enclosure without requiring a separate radiation shield
Specifications
- Color
- White
(Reflects solar radiation, reducing temperature gradients inside the enclosure without requiring a separate radiation shield.)
- Construction
- Fiberglass-reinforced polyester enclosure with door gasket, external grounding lug, stainless-steel hinge, and lockable hasps
- Enclosure Classification
- NEMA 4X
(before being modified for cable entry)
- Number of Cable-Entry Seals
- 2 large, 2 medium, 2 small
- Dimensions
- 40.6 x 35.6 x 14 cm
(16 x 14 x 5.5 in.) internal
38.63 x 33.66 x 17.6 cm(15.21 x 13.25 x 6.93 in.) internal under the lid space
44.27 x 39.19 x 19.58 cm(17.43 x 15.43 x 7.71 in.) external
- Weight
- 6 kg
(13 lb)
Accessories
(7)CS211
Smart Enclosure Sensor
Orderable10525
Desiccant and Document Holder for Enclosures
Orderable6714
Four-Unit Desiccant Bags (quantity of 20)
Orderable42815
Four-Unit Desiccant Bags (quantity of 10)
Orderable31551
Enclosure Leg Stack Mounting Kit
Orderable31143
Hinged Enclosure Stack Mounting Kit
Orderable40294
Horizontal, Grid-Mount Strain-Relief Kit
Orderable
Common Accessories
(6)10525
Desiccant and Document Holder for Enclosures
This desiccant holder is attached to the inside of the lid of a Campbell Scientific enclosure with adhesive Velcro strips (supplied). The holder accommodates two packages of our 4-unit desiccant.
Orderable6714
Four-Unit Desiccant Bags (quantity of 20)
The 6714 includes twenty 4-unit Silica Gel Desiccant Bags.
Orderable42815
Four-Unit Desiccant Bags (quantity of 10)
The 42815 includes 10 large, four-unit desiccant bags, used to absorb humidity within enclosures. Multiple packs are recommended for customers who need to desiccate multiple enclosures or systems.
Orderable31551
Enclosure Leg Stack Mounting Kit
The 31551 is a kit to allow stacking of components inside Campbell Scientific enclosures. The kit includes two leg brackets. It is used to raise a datalogger up and off the backplate so that wiring is easier or so that components can be stacked.
Orderable31143
Hinged Enclosure Stack Mounting Kit
The 31143 is a hinged stack bracket that is designed to fit a CR1000 datalogger, CR6 datalogger, or multiplexter on either the top or underneath. The hinge enables access to the equipment underneath without disconnecting any wires (assuming that the wires are long enough).
OrderableCS211
Smart Enclosure Sensor
The CS211 is a low-power, smart sensor designed to monitor temperature and humidity levels inside enclosures. The sensor features an optical door switch to detect door openings and closings, and a multifunctional button that recognizes short, long, and double presses for user-defined actions. Additionally, the CS211 includes an LED indicator to signal enclosure wetness and when desiccant needs to be replaced.
Orderable
Replacement Parts
(14)28878
Replacement Enclosure Humidity Indicator Card
The 28878 is a replacement humidity indicator card. It provides a visual reference of humidity level inside the enclosure. Colored circles change color from blue to pink to indicate humidity levels of 30%, 40%, and 50% relative humidity. Double sticky tape on the back of the card allows it to be easily secured to an enclosure lid.
Orderable18823
Universal Backplate for ENC14/16 Enclosure
This aluminum backplate is pre-punched with a matrix of half-inch-on-center holes. It is available as a replacement part for an existing ENC14/16 enclosure in case a mishap should befall the original backplate. Like our other backplates, the 18823's grid of holes accommodate 6044 grommets and 505 screws.
Orderable18957
ENC14/16 Tripod Leg Mounting Kit
This bracket is the same as the "-LM" option. It may be ordered as a replacement part if the bracket gets damaged or if another option was originally chosen.
Orderable7363
Enclosure Supply Kit, Standard Size
The enclosure supply kit includes desiccant, a humidity indicator card, cable ties, wire tie tabs, putty for sealing the conduit, and screws and grommets for attaching peripherals to the enclosure backplate.
Orderable795
Stainless-Steel Nylock Nut 1/4-20
A couple of these nuts are attached to the enclosure bracket. The nut may be purchased to replace a lost or damaged nut.
Orderable5449
Enclosure Ground Lug
The 5449 ground lug is attached to the enclosure. It may be purchased to replace a lost or damaged ground lug.
Orderable23
Stainless-Steel Nut #10-32
The pn 23 nut is available as a replacement item.
Orderable25744
1-1/2 Panel Bushing Pin (Male)
The 25744 and 25746 are the two parts used to create the standard conduit for Campbell Scientific enclosures. If a portion of the conduit for an ENC or PWENC enclosure becomes lost, the 25744 and 25746 can be ordered as replacements.
Orderable25746
1-1/2 PVC Coupling PVC Female Adapter
The 25746 and 25744 are the two parts used to create the standard conduit for Campbell Scientific enclosures. If a portion of the conduit for an ENC or PWENC enclosure becomes lost, the 25746 and 25744 can be ordered as replacements.
Orderable560
Screw #10-32 x .312 Pan Phillips
The 560 screw is used to attach a backplate to the inside of an enclosure.
Orderable6832
Enclosure Filter with 60 Micron Pore Size
One 6832 filter may be installed in one of the small compression fittings (cable entry seals) in the enclosure to allow air pressure to equalize between the inside and outside of the enclosure. As such, the filter is used only when the cable entry seals option is selected for the enclosure (item 6447). The filter is typically used when a barometric pressure sensor (or, in some cases, the cable termination of a vented submersible pressure transducer) will be located inside the enclosure. The filter has a 60 micron pore size.
Orderable6650
Enclosure Ground Wire, 36 in.
This 36 in.ground wire and lug connector can be purchased to replace a ground wire and lug connector that has been lost or damaged.
Orderable3890
Silicone O-Ring
The 3890 is a silicone O-ring used. Customers will periodically need to replace worn-out O-rings.
Orderable6688
Plug for Cable Entry Connector
The 6688 is the plug that fits inside the 31363 Cable Entry Seal when there is not a cable running through it. The 6688 can be ordered to replace a lost plug.
Orderable
Need Something Not Listed?
(45228)Don't see what you need from among these options? Download the complete configuration list below.
View all product configurationsShips With
(1)Similar Products
(5)Compatibility
Compatible Products
(2)Related Resources
Case Studies
Documents
- Technical Paper
Keeping Pests Away from Equipment (5-Y)
August 2020
View Document - Compliance
Weather-Resistant Enclosures EU Declaration of Conformity
June 2016
View Document - Manual
ENC10/12, ENC12/14, ENC14/16, ENC16/18 Enclosures
June 2021
View Document - Brochure
ENC14/16 Weather-Resistant Enclosure
March 2026
View Document