- Model:
- ENVIROSCAN
- Item Number:
- 16082
- Warranty:
- 2 years
Overview
The EnviroSCAN probe provides soil-water-content profiles for irrigation scheduling or other water movement systems. The measurement range is oven dry to saturation. The probes measure soil moisture at multiple depths and are easy to install. Tools offered by Campbell Scientific allow the probes to be installed with minimal soil disturbance. EnviroSCAN is recommended for higher accuracy research measurements, measurements deeper than 80 cm, or stony soils. It is customizable by adding sensors at user-specified depths.
Key Advantages
Water content profile with minimal soil disturbance
Technical Description
The EnviroSMART probe has been renamed EnviroSCAN.
The EnviroSCAN includes several water content sensors that measure soil water at multiple depths. Around each sensor, the probe creates a high frequency electrical field that extends through the access tube into the soil. Electrical capacitance is then measured and soil water content is determined from those measurements.
Each water content sensor outputs an SDI-12 signal that our CR200(X)-series, CR800, CR850, CR1000, and CR3000 dataloggers can measure. This allows the probes to be integrated with a Campbell Scientific data logger or weather station. Integrating the probes into our data acquisition systems allows the data to be telemetered back to a field station or remote computer.
EnviroSCAN is customized for individual applications by adding sensors at user-specified measurement depths. The maximum measurement depth of the standard configuration is 2 m (6 ft); deeper measurements are possible with special provisions.
Specifications
- Maximum Sensors per Standard Probe
- 16
- Sensor Measuring Principle
- High-frequency capacitance
- Output
- SDI-12 version 1.2
- Total Current Consumption (per sensor)
- 250 µA
(sleep)
66 mA(standby)
100 mA(sampling)
- TriSCAN Current Consumption
- 130 mA
(sampling)
- Water Content Reading Range
- 0 to ~65%
- Temperature Effects
- ±3%
(5° to 35°C)
- Time to Read 1 Sensor
- 1.1 s
- Sphere of Influence
- 99% of the reading is taken within a 10 cm radius from the outside of the access tube.
- Operating Temperature Range
- -20° to +75°C
- Sensor Diameter
- 5.05 cm
(2.0 in.)
- Access Tube Diameter
- 5.65 cm
(2.2 in.)
- Probe Length
- 0.5, 1.0, 1.5, or 2.0 m
(1.6, 3.3, 4.9, or 6.6 ft)
Ships With
(1)- Handle set with screws
Compatibility
Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.
Compatible Products
(15)
Basic Datalogger
Basic Datalogger
RetiredNotes—
Basic Datalogger
Basic Datalogger
RetiredNotes—
CR10
Measurement and Control System
RetiredNotes—
CR200X
Datalogger
RetiredNotes—
CR206X
Datalogger with 900 MHz Spread-Spectrum Radio
RetiredNotes—
CR211X
Datalogger with 922 MHz Spread-Spectrum Radio
End of lifeNotes—
CR216X
Datalogger with 2.4 GHz Spread-Spectrum Radio
RetiredNotes—
CR295X
Datalogger for GOES Satellite Communication
RetiredNotes—
CR800
Measurement and Control Datalogger
RetiredNotes—
CR850
Measurement and Control Datalogger
RetiredNotes—
CR1000
Measurement and Control Datalogger
RetiredNotes—
CR3000
Measurement and Control Datalogger
RetiredNotes—
CR5000
Measurement and Control Datalogger
RetiredNotes—
Datalogger for Measurement and Control
Datalogger for Measurement and Control
RetiredNotes—
Micrologger for Data Acquisition
Micrologger for Data Acquisition
RetiredNotes—
Related Resources
Documents
- Manual
Sentek TriSCAN® Manual v 1.2a
View Document - Manual
Sentek EnviroSCAN EasyAG SDI-12 Manual v 3.4
View Document - Manual
Sentek EnviroSCAN Access Tube Installation Guide
January 2003
View Document - Manual
EnviroSCAN Sentek Water Content Profile Probe
September 2016
View Document
Showing 4 of 5 results
See all DocumentsProduct Life Events
- Available for Order
- September 18, 2010
- Retired
- December 31, 2016
- Free Support Until
- March 31, 2018
- End of Life
- March 31, 2018
- Calibration Available Until
- March 31, 2018
- Repair Available Until
- March 31, 2018