Overview
The A100LK is an anemometer suitable for your general meteorology applications and wind-energy surveys. Its low power consumption and wide power-supply range make it popular for remote locations with no access to ac power, and its pulse/frequency signal is ideal for use with Campbell Scientific data loggers. The sensor is constructed from anodized aluminum alloys, stainless steel, and weather-resistant plastics for long life. It is used as part of our WMS100 wind-monitoring system.
Key Advantages
Ideal for wind-energy applications
Technical Description
Rotation of the A100LK’s three-cup rotor is electronically converted to pulse output signals proportional to wind speed. The A100LK produces a higher rate of pulses per revolution (up to 13) compared to relay-based sensors, making it suitable for wind surveying where turbulence needs to be estimated.
Benefits
- IEC Class 1 performance
- Low power consumption
- High rate of pulses per revolution produced makes it suitable for wind-surveying applications where turbulence is estimated
- Bearings protected from the entry of moisture droplets and dust, resulting in an instrument suitable for permanent exposure to the weather
Specifications
- Sensor
- 3-cup anemometer
- Measurement Description
- Wind speed
- Signal Type/Output
- Electronic pulse
- Range
- 0 to 77 ms-1
- Threshold
- 0.15 ms-1
(starting speed 0.2 ms-1, stopping speed 0.1 ms-1)
- Maximum Speed
- 77.22 ms-1
- Accuracy
- 1% ±0.1 ms-1
- Distance Constant
- 2.3 m ±10%
- Calibration Data
- Supplied for anemometer and rotor at one test speed to an accuracy of ±1% at +15°C.
(12 Vdc supply and an analog output load of 1 MΩ) - Operating Temperature Range
- -30° to +70°C
- Rotor
- 15.2 cm
(6 in.) diameter three-cup rotor
- Supply Voltage
- 6.5 to 28 Vdc
- Current Consumption
- 2 mA maximum
1.6 mA typical (no output load) - Power-up Time
- 5 s
- Surge Protection
- Vector PC3L2 anti-surge module fitted
- Housing Diameter
- 5.5 cm
(2.2 in.)
- Height
- 19.5 cm
(7.68 in.)
- Weight
- 490 g
(17.3 oz) including 3 m (10 ft) cable
Accessories
(1)Compatibility
Data Logger Considerations
The A100LK uses one pulse count channel on the data logger.
Programming
The A100LK is read by the PulseCount Instruction in CRBasic and by Instruction 3 (Pulse Count) in Edlog. Wind speed measurements can be taken and processed with any of the data loggers.