CR1000X

Measurement and Control Datalogger
CR1000X

CR1000X

Retired

Measurement and Control Datalogger

No longer available to order

This product is retained for service, documentation, and compatibility information.

Replaced by

  • CR1000Xe

    Measurement and Control Datalogger

Model:
CR1000X
Item Number:
CR1000X
Warranty:
3 years

Overview

The CR1000X is our flagship data logger that provides measurement and control for a wide variety of applications. Its reliability and ruggedness make it an excellent choice for remote environmental applications, including weather stations, mesonet systems, wind profiling, air quality monitoring, hydrological systems, water quality monitoring, and hydrometeorological stations.

The CR1000X is a low-powered device that measures sensors, drives direct communication and telecommunications, analyzes data, controls external devices, and stores data and programs in onboard, nonvolatile storage. The electronics are RF-shielded by a unique sealed, stainless-steel canister. A battery-backed clock assures accurate timekeeping. The onboard, BASIC-like programming language, common to all contemporary Campbell Scientific data loggers, supports data processing and analysis routines.

Key Advantages

Flagship Data Logger
Accurate, rugged, reliable

Technical Description

The CR1000X is a low-powered device designed to measure sensors, drive direct communication and telecommunications, analyze data, control external devices, and store data and programs in on-board, non-volatile storage. The electronics are RF-shielded and glitch-protected by a unique sealed, stainless-steel canister. A battery-backed clock assures accurate timekeeping. The on-board, BASIC-like programming language—common to all Campbell Scientific data loggers—supports data processing and analysis routines.

The CR1000X wiring panel includes two switchable 12 V terminals, analog grounds dispersed among 16 analog terminals, and unpluggable terminal blocks for quick deployment.

Benefits

  • Operational in extreme environments with a standard operating range of -40° to +70°C and an extended operating range of -55° to +85°C
  • Connects directly to a computer's USB port
  • Captures quickly changing data values with fast analog measurement capabilities (300+ Hz)
  • Differentiates even slight changes in data values with higher-resolution measurements (24 bit Adc)
  • Includes two non-isolated current input channels for directly connecting sensors with 0-to-20 mA or 4-to-20 mA current outputs
  • Contains an onboard CPI port for hosting Campbell high-speed sensors and distributed modules (CDM)
  • Directly connects to Ethernet
  • Includes microSD card drive for extended memory requirements
  • Provides simple serial sensor integration and measurement with SDI-12, RS-232, and/or RS-485
  • Supports full PakBus networking
  • Includes embedded web page for direct connection via web browser

Specifications

-NOTE-
Additional specifications are listed in the CR1000X Specifications Sheet.
Operating Temperature Range
-40° to +70°C

(standard)

-55° to +85°C

(extended)

Non-condensing environment
Maximum Scan Rate
1000 Hz
Case Material
Anodized aluminum
Analog Inputs
16 single-ended or 8 differential

(individually configured). Two analog inputs can measure 4 to 20 mA or 0 to 20 mA natively. Four analog inputs can provide pulse/digital I/O functions.

Pulse Counters
10

(P1 to P2 and C1 to C8)

Voltage Excitation Terminals
4

(VX1 to VX4)

Maximum Source/Sink Current
±40 mA

(voltage excitation)

50 mA

(switched regulated)

Communications Ports
Ethernet
USB Micro B
CS I/O
RS-232
RS-422
CPI
RS-485
Data Storage Ports
microSD
Switched 12 Volt
2 terminals
Digital I/O
8 terminals (C1 to C8) configurable for digital input and output.

Includes status high/low, pulse width modulation, external interrupt, edge timing, switch closure pulse counting, high-frequency pulse counting, UART, RS-232, RS-485, SDM, SDI-12, I2C, and SPI function. Terminals are configurable in pairs for 5 V or 3.3 V logic for some functions.

Input Limits
±5 V
Analog Voltage Accuracy
Accuracy specifications do not include sensor or measurement noise.
±(0.04% of measurement + offset)

at 0° to 40°C

±(0.06% of measurement + offset)

at -40° to +70°C

±(0.08% of measurement + offset)

at -55° to +85°C (extended temperature range)

ADC
24-bit
Power Requirements
10 to 18 Vdc input

(See manual for further details.)

Real-Time Clock Accuracy
±3 min. per year

(Optional GPS correction to ±10 µs)

Internet Protocols
Ethernet, PPP, RNDIS, ICMP/Ping, Auto-IP (APIPA), IPv4, IPv6, UDP, TCP, TLS (v1.2), DNS, DHCP, SLAAC, Telnet, HTTP(S), SFTP, FTP(S), POP3/TLS, NTP, SMTP/TLS, SNMPv3, CS I/O IP, MQTT
Communications Protocols
CPI, PakBus, SDM, SDI-12, Modbus, TCP, DNP3, UDP, NTCIP, NMEA 0183, I2C, SPI, and others
Battery-backed SRAM for CPU Usage & Final Storage
4 MB
Data Storage
4 MB SRAM + 72 MB flash

(Storage expansion of up to 16 GB with removable microSD flash memory card.)

Idle Current Drain, Typical
< 1 mA

(@ 12 Vdc)

Active Current Drain, Typical
1 mA

(1 Hz scan @ 12 Vdc)

Active Current Drain, Average
55 mA

(20 Hz scan @ 12 Vdc)

Dimensions
23.8 x 10.1 x 6.2 cm

(9.4 x 4.0 x 2.4 in.)
Additional clearance required for cables and leads.

Weight
0.86 kg

(1.9 lb)

Common Accessories

(12)

Replacement Parts

(13)

Services

(3)

Compatibility

Sensors

With several terminal types, the CR1000X is compatible with nearly every available sensor, including analog (both voltage and current), thermocouples, serial, SDI-12, pulse, and frequency sensors.

Measurement & Control Peripherals

The CR1000X is compatible with all our CDMs, multiplexers, vibrating-wire interfaces, terminal input modules, and relays. 

Communications

The CR1000X communicates with a PC via direct USB port, 10/100baseT Ethernet port, multidrop modems, short-haul modems, phone modems (land line, digital cellular, and voice-synthesized), RF telemetry, and satellite transmitters (HDR GOES, Argos, Meteosat, Iridium, and Inmarsat).

Data can be viewed on the CR1000KD Keyboard Display, the CD100 Mountable Display with Keyboard, an iOS or Android device (requires our free LoggerLink app), CD295 DataView II Display, or other third-party devices. 

Enclosures

The CR1000X and its power supply can be housed in any of our standard enclosures. 

Power

Any external 12 Vdc source can power the CR1000X datalogger. Campbell Scientific power supplies commonly used with the CR1000X are the BPALK, PS150, and PS200. 

Software

Campbell Scientific proprietary software is required to program, configure, and communicate with the CR1000X datalogger. Various software options are available to meet a breadth of application needs. At a minimum, Short Cut and PC200W are needed. Consult with a Campbell Scientific Support and Implementation Engineer to determine the best software option. 

Related Resources

Case Studies

Showing 4 of 18 results

See all Case Studies

Documents

Showing 4 of 16 results

See all Documents

Downloads

Showing 4 of 5 results

See all Downloads

Videos and Tutorials

Showing 4 of 75 results

See all Videos and Tutorials

Press Releases

Services Available

Repair
Yes
Calibration
Yes