SDM-SIO2R
SDM-SIO2R
OrderableTwo-Channel Serial I/O Module with Relays
Overview
The SDM-SIO2R is a digital sensor expansion module that expands the serial I/O interface via Synchronous Device for Measurement (SDM) communications on a data logger. The serial I/O functionality is identical to the SDM-SIO1A One-Channel Serial I/O Module and the SDM-SIO4A Four-Channel Serial I/O Module, except it has two channels. The SDM-SIO2R also has terminals to connect sensor power and sensor heater power, which are controllable via the SDMGeneric instruction in CRBasic.
Technical Description
The SDM-SIO2R features a connector bus system that connects multiple SDM-SIO2R modules on a DIN rail without having to wire each individual unit. C1, C2, C3, 12V, V+, and G are all bussed between multiple units, making it easy to expand sensor count. Up to eight units can be bussed together with up to 15 sensors. This is the maximum number of SDM addresses available.
Benefits
- Hot swappable in the field
- Modular design
- Expandable as needed
- Removable terminals
- Power control ability for each individual sensor
Specifications
- Function
- Expands the serial I/O interface via Synchronous Device for Measurement (SDM) communications on a data logger
- Number of Channels
- 2
- Supported Data Rates
- 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200 bits/s
- Supported Modes of Operation
- Hardware CTS/RTS flow control is supported in RS-232 mode. The handshaking lines can also be used as general purpose I/O lines.RS-232
(full duplex and receive only)
RS-485(half and full duplex)
RS-422(full duplex)
- Supported Data Formats
- 8, seven-bit data size*; none, odd or even parity; one or two stops bits
*In seven-bit mode with no parity, the user must ensure that the characters received by the SDM-SIO2R have a delay of at least one bit period between them. This does not affect any other configuration and does not affect transmissions out of the SDM-SIO2R. - Auto Baud Rate Detection
- Not supported
- PakBus Communications
- Use of the serial port for general PakBus communications is not currently supported.
- Operating Voltage
- Power supply +12 V connection9 V
(minimum
12 V(nominal)
30 V(maximum)
- Operating Temperature
- -40° to +70°C
- Standard Humidity Range
- 0 to 95%
(non-condensing)
- Dimensions
- 133.35 x 76.2 x 19.05 mm
(5.25 x 3 x 0.75 in.)
- Weight
- 108.5 g
(3.8 oz)
Buffer Sizes
- -NOTE-
- Both transmit and receive buffers are fill and discard type.
That is, after the buffers become full, no new information is accepted. All further data is discarded until space is made when the data logger requests data from the SDM-SIO2R.
- Transmit Buffer Size
- 767 bytes
(buffer from the data logger to the sensor)
- Receive Buffer Size
- 6143 bytes
(buffer from the sensor to the data logger)
Current Consumption
- Standby Current (12V & V+ ON)
- 13.22 mA
(nominal)
13.23 mA(maximum)
- Standby Current (12V & V+ OFF)
- 63.22 mA
(nominal)
64.71 mA(maximum)
Accessories
(7)39086
6 in. DIN Rail Mounting Kit
Orderable39087
10 in. DIN Rail Mounting Kit
Orderable39088
12 in. DIN Rail Mounting Kit
Orderable39089
14 in. DIN Rail Mounting Kit
Orderable39090
20.625 in. DIN Rail Mounting Kit
OrderableCABLE5CBL
5-Conductor 22 AWG Cable with Drain
OrderableSC110
Two Cables, RS-232 to Data Logger Control Port
Orderable
Common Accessories
(6)39086
6 in. DIN Rail Mounting Kit
Note: Each SDM-SIO2R takes up approximately 0.375 in. on a DIN rail.
The 39086 can facilitate wiring when many wires need to be connected to one terminal. This kit contains one DIN rail mounting bracket, two 505 screws, two 6044 grommets, and two 15908 DIN Rail Stoppers. A complete configuration would also include terminal connectors, end plates, and jumpers. The stoppers, terminal connectors, and end plates are mounted onto the DIN rail bracket. The DIN rail bracket is mounted to an enclosure backplate using the kit’s screws and grommets.Orderable39087
10 in. DIN Rail Mounting Kit
Note: Each SDM-SIO2R takes up approximately 0.375 in. on a DIN rail.
The 39087 can facilitate wiring when many wires need to be connected to one terminal. This kit contains one 10 in. DIN rail mounting bracket, two 505 screws, two 6044 grommets, two washers, two DIN rail end caps, and two 15908 DIN Rail Stoppers. A complete configuration would also include terminal connectors, end plates, and jumpers. This kit is often used with prewired or UL-approved enclosures.Orderable39088
12 in. DIN Rail Mounting Kit
Note: Each SDM-SIO2R takes up approximately 0.375 in. on a DIN rail.
The 39088 can facilitate wiring when many wires need to be connected to one terminal. This kit contains one 12-inch DIN rail mounting bracket, two 505 screws, two 6044 grommets, and two 15908 DIN Rail Stoppers. A complete configuration would also include terminal connectors, end plates, and jumpers. The stoppers, terminal connectors, and end plates are mounted onto the DIN rail bracket. The DIN rail bracket is mounted to an enclosure backplate using the kit’s screws and grommets.Orderable39089
14 in. DIN Rail Mounting Kit
Note: Each SDM-SIO2R takes up approximately 0.375 in. on a DIN rail.
The 39089 can facilitate wiring when many wires need to be connected to one terminal. This kit contains one 14-inch DIN rail mounting bracket, two 505 screws, two 6044 grommets, and two 15908 DIN Rail Stoppers. A complete configuration would also include terminal connectors, end plates, and jumpers. The stoppers, terminal connectors, and end plates are mounted onto the DIN rail bracket. The DIN rail bracket is mounted to an enclosure backplate using the kit’s screws and grommets.Orderable39090
20.625 in. DIN Rail Mounting Kit
Note: Each SDM-SIO2R takes up approximately 0.375 in. on a DIN rail.
The 39090 can facilitate wiring when many wires need to be connected to one terminal. This kit contains one 20 5/8-inch DIN rail mounting bracket, two 505 screws, two 6044 grommets, and two 15908 DIN Rail Stoppers. A complete configuration would also include terminal connectors, end plates, and jumpers. The stoppers, terminal connectors, and end plates are mounted onto the DIN rail bracket. The DIN rail bracket is mounted to an enclosure backplate using the kit’s screws and grommets.OrderableCABLE5CBL
5-Conductor 22 AWG Cable with Drain
Note: Just one CABLE5CBL is needed per system to connect to the data logger. Multiple SIO2Rs are bussed together via the included DIN rail bus connector without the need for multiple cables.
The CABLE5CBL is a 22 AWG, five-conductor cable with a Santoprene jacket and an aluminum Mylar shield. By default, the conductors are stripped and tinned. The cable can also be fitted with a connector for attachment to a prewired enclosure.Orderable
Ships With
(1)- 8-Pin DIN Rail Bus
Similar Products
(6)Compatibility
The SDM-SIO2R requires a desiccated, non-condensing environment; a Campbell Scientific enclosure is recommended. The SDM-SIO2R is DIN rail mountable and will not mount to a typical Campbell Scientific one-inch diamond grid pattern back panel without the use of a DIN rail, which is sold separately.
The SDM-SIO2R does NOT support auto baud rate detection nor the use of the serial port for general PakBus communications.
Compatible Products
(4)Incompatible Products
(2)Related Resources
Case Studies
Documents
- Compliance
SDM-SIO2R UK Declaration of Conformity
View Document - Manual
SDM‑SIO2R Product Manual (online)
November 2024
View Document - Manual
SDM-SIO2R Serial Input/Output Module with Switched Sensor Power
March 2026
View Document - Brochure
SDM-SIO2R Two-Channel Serial I/O Module with Relays
March 2026
View Document
Showing 4 of 5 results
See all DocumentsDownloads
- SDM-SIO2R Example Programv1
October 5, 2023
Software ApplicationsIn this example program, a SDM-SIO2R will read a visibility measurement from the CS120A. If the SIO2R does not get data from the CS120A three consecutive times, the SIO2R will turn off power to the sensor for 10 seconds and then turn power to the sensor back on and try communicating with it again.