Granite 6

Measurement and Control Data Acquisition System
Granite 6

Granite 6

End of life

Measurement and Control Data Acquisition System

No longer available to order

This product is retained for service, documentation, and compatibility information.

Model:
Granite 6
Item Number:
GRANITE6
Warranty:
3 years

Overview

The Granite™6 DAQ is a powerful core component for your complete data acquisition system. The Granite 6 provides fast communication, low power requirements, built-in USB and Wi-Fi, modular design, and high analog input accuracy and resolution. It uses universal (U) terminals to allow a connection to virtually any sensor—analog, digital, or smart. The multipurpose DAQ is also capable of measuring static vibrating wire measurements.

Learn about our patented VSPECT™ spectral-analysis technology at our VSPECT Essentials web resource.

The dynamic vibrating wire measurement technique is protected under U.S. Patent No. 8,671,758, and the vibrating wire spectral-analysis technology (VSPECT) is protected under U.S. Patent No. 7,779,690.

Key Advantages

Rugged for the Field, Refined for the Lab
Flexible, precise, accurate

Technical Description

The Granite 6 provides extreme measurement versatility, has multiple communications options, processes sensor responses to engineering units, performs calculations, generates alarms, and controls external devices. Data are stored in onboard, nonvolatile memory awaiting transfer to the end user via direct or remote access. The Granite 6 can generate real-time or event-driven data tables. These data can be further processed with high-level math functions and statistical summaries such as averages, standard deviations, and rainflow histograms.

Benefits

  • Operational in extreme environments with a standard operating range of -40° to +70°C
  • USB and built-in Wi-Fi for easy connection to PC
  • Universal terminals configurable for analog or digital, input or output
  • Supports static vibrating wire measurements using Campbell Scientific’s patented VSPECT spectral analysis technology
  • Industry leader for high-resolution measurement needs
  • USB host facilitates additional memory in large data applications

Specifications

-NOTE-
Additional specifications are listed in the GRANITE 6 Specifications.
Pulse Counters
12 (U1 to U12)
Voltage Excitation Terminals
12 (U1 to U12)
Universal Inputs
12 individually configured inputs for analog or digital functions
Case Material
Stainless steel 304 and aluminum 6061
Operating Temperature Range
-40° to +70°C

(standard)

Non-condensing environment
Communications Ports
Ethernet
USB Micro B
USB host
CS I/O
0 to 5 V serial
SDI-12
RS-485
RS-422
CPI/RS-232
Data Storage Ports
microSD
USB host
Digital I/O
16 terminals (C1 to C4, U1 to U12) configurable for digital input and output.

Terminals are configurable in pairs for 5 V or 3.3 V logic for some functions.

Analog Voltage Accuracy
Accuracy specifications do not include sensor or measurement noise.
±(0.04% of measurement + offset) at 0° to 40°C
±(0.06% of measurement + offset) at -40° to +70°C
ADC
24-bit
Power Requirements
16 to 32 Vdc for charger input (CHG)
10 to 16 Vdc for battery input (BAT)
Real-Time Clock Accuracy
±3 min. per year (optional GPS correction to ±10 µs; 5.7 ppm)
Internet Protocols
Ethernet, PPP, RNDIS, ICMP/Ping, Auto-IP (APIPA), IPv4, IPv6, UDP, TCP, TLS (v1.2), DNS, DHCP, SLAAC, Telnet, HTTP(S), SFTP, FTP(S), POP3/TLS, NTP, SMTP/TLS, SNMPv3, CS I/O IP
Communication Protocols
CPI, PakBus, PakBus Encryption, SDM, SDI-12, Modbus RTU / ASCII / TCP, DNP3, custom user definable over serial, UDP, NTCIP, NMEA 0183, I2C, SPI
Warranty
3 years standard (against defects in materials and workmanship)
Optional: An additional 2 years (against defects in materials and workmanship), bringing the total to 5 years
Battery-backed SRAM for CPU Usage & Final Storage
4 MB
Data Storage
4 MB SRAM + 72 MB flash

(Storage expansion of up to 16 GB with removable microSD flash memory card.)

Idle Current Drain, Average
Assumes 12 Vdc on BAT terminals; add 2 mA if using CHG terminals.
< 1 mA
Active Current Drain, Average
Assumes 12 Vdc on BAT terminals; add 2 mA if using CHG terminals.
3 mA

(1 Hz scan)

67 mA

(20 Hz scan)

Static Vibrating Wire Measurements
Supported
Dimensions
21.4 x 12.0 x 5.0 cm

(8.4 x 4.7 x 2.0 in.)
Additional clearance required for cables and leads.

Weight
0.86 kg

(1.9 lb)

Maximum Program Scan Rate
1 kHz
Measurement Module Synchronization
±5 µs

(CPI)

GPS Synchronization
±20 µs
Maximum Number of Measurement Modules
15
Input Limits
±5 V

Common Accessories

(11)

Other Accessories

(6)

Replacement Parts

(13)

Services

(2)

Related Resources

Documents

Showing 4 of 15 results

See all Documents

Downloads

Showing 4 of 6 results

See all Downloads

Videos and Tutorials

Showing 4 of 64 results

See all Videos and Tutorials

Press Releases

Blog Articles

Product Life Events

Partner Preview / Coming Soon
September 18, 2019
Available for Order
May 28, 2021
Retired