922 MHz Spread Spectrum Radio/Modem

922 MHz Spread Spectrum Radio/Modem
Automated
Automated

922 MHz Spread Spectrum Radio/Modem

Retired

No longer available to order

This product is retained for service, documentation, and compatibility information.

Replaced by

  • RF411A

    922 MHz Spread-Spectrum Radio

  • RF412

    922 MHz Spread-Spectrum Radio

Overview

The RF410 was a 100 mW spread spectrum radio/modem for point-to-point and point-to-multipoint data logger communications. It could serve as a field radio/modem connected to a data logger or as a base station radio/modem connected to a computer. The RF410 had an operating frequency range of 920 to 928 MHz, which was used in Australia/Israel.

Specifications

Operating Frequency
920 to 928 MHz
Type
Frequency Hopping Spread Spectrum (FHSS) Transceiver
I/O Data Rate
9600 bps
Channel Capacity
65,000 Network Identifiers share 25 hop channels.
Frequency Hopping Patterns
Six different selectable patterns
Frequency Control
Direct FM
Receiver Sensitivity
-110 dBm at 10-4 bit error rate

(Campbell Scientific protocols will issue retries wherever a bit error occurs.)

Interface Rejection
70 dB at pager and cellular phone frequencies
Transmitter Power Output
100 mW

(nominal)

Antenna Connector
Reverse polarity SMA
FCC ID
OUR9XTREAM
Operating Temperature Range
-25° to +50°C
Power
9 to 16 Vdc
LEDs
Power on, TX, RX, diagnostics
CS I/O Connector
9-pin “D” male for all needed communications lines.

Newer loggers provide power to the radio on this connector. Older loggers may require optional power cable pn 14291.

RS-232 Connector
9-pin “D” female for TX, RX, CTS, ground RS-232 levels
Power Connector
Barrel connector, center positive 12 V for use in base station configuration or with older data loggers.

Newer loggers provide power to the radio on the CS I/O connector.

Dimensions
Allow an additional 3 in. (7.5 cm) along the longest axis for external cable connection.
11.4 x 7.0 x 2.9 cm

(4.9 x 2.8 x 1.2 in.)

12.7 x 7.0 x 2.8 cm

(5.0 x 2.8 x 1.1 in.) with mounts

Weight
227 g

(8 oz)

Average Current Drain

Standby
< 1 mA

(assuming power-saving options used)

Receiving
24 mA
Transmitting
< 75 mA

Replacement Parts

(12)

Compatibility

Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.

Communications

The RF410 can transmit data to another RF410 radio or a CR210 datalogger. The RF410 may also be used in a network with RF411 radios and/or CR211(X) dataloggers if all of the RF411 radios and CR211(X) dataloggers are set to the transparent mode.Campbell Scientific does not recommend using the RF411 in networks containing FGR-115 or RF450 radios.

Enclosure Considerations

A desiccated, non-condensing environment is required. The 14162 Mounting Kit includes hardware for securing the RF410 to an enclosure backplate (see Ordering Info).

Compatible Products

(24)

Related Resources

Product Life Events

Calibration Available Until
September 1, 2005
Retired
September 1, 2005
Free Support Until
March 31, 2020
End of Life
March 31, 2020
Repair Available Until
March 31, 2020
Available for Order
January 1, 2050